精華區beta EE_DSnP 關於我們 聯絡資訊
※ 引述《timmylin (Noname)》之銘言: : 因為ISCAS的bench中PO的名稱和Output最後一級 : 的Gate名稱是一樣的 : ex: c17 : .output 2 22GAT 23GAT : . : . : . : or 23GAT 16GAT 19GAT : or 22GAT 10GAT 16GAT : 所以PO的Gate是要等所有電路讀完再加上去嗎?? :    :   還是要把所有的PO都改個名字?? : 不然這樣進map時會發生重疊現象..... (Forgot to mention about this one in class... Thanks for reminding.) A PO gate is like a buffer without output. In other words, PO(22GAT) has no fanout, and one fanin as OR(22GAT). However, in order to distinguish PO(22GAT) and OR(22GAT) in the map, please apply the name "22GAT$PO" to the map. Please note that you DON'T NEED TO change the name of the PO gate. You can still use its original name (i.e. 22GAT). This will make the "report xxx" commands easier. In short, just composing the name "22GAT$PO" when read from and write to the map. -- ※ 發信站: 批踢踢實業坊(ptt.cc) ◆ From: 59.121.131.34