精華區beta NTU-Exam 關於我們 聯絡資訊
課程名稱︰感測器與致動器原理 課程性質︰工科系選修 課程教師︰鄭勝文 開課系所︰工科海洋 考試時間︰期末考週 試題 :In a chemical plant, in order to on-line monitoring the condition of pipelines, a sensor module must be installed for measurement of 1.the average liquid flow velocity 2.the velocity of solid particles (duameter large than 1 cm ), and 3.the displacement amplitude of outer suface Design an ultrasoundbase sensor module under following requirements. 1.velocity range:0~100 cm/sec resolution:less than 1 cm/sec 2.displacement amplitude frequency:100Hz~500Hz 3.outer diameter of pipe:30cm 4.thickness of pipe shell:1 cm 5.material of pipelines:plain carbon stell -- ※ 發信站: 批踢踢實業坊(ptt.cc) ◆ From: 140.112.249.80